Filter Results By:

Products

Applications

Manufacturers

Current Generators

Produce electric current.


Showing results: 46 - 48 of 48 items found.

  • Resistors

    Vishay Intertechnology, Inc.

    A passive two-terminal electrical component that implements electrical resistance as a circuit element. In electronic circuits, resistors are used to reduce current flow, adjust signal levels, to divide voltages, bias active elements, and terminate transmission lines, among other uses. High-power resistors that can dissipate many watts of electrical power as heat may be used as part of motor controls, in power distribution systems, or as test loads for generators. Fixed resistors have resistances that only change slightly with temperature, time or operating voltage. Variable resistors can be used to adjust circuit elements (such as a volume control or a lamp dimmer), or as sensing devices for heat, light, humidity, force, or chemical activity.

  • Single-Phase Transformer Winding Resistance Meters

    RMO-TD Series - IBEKO Power AB

    Using the most advanced switch-mode technology available today, the RMO-TD series is ideal for winding resistance measurements of inductive objects. Transformer resistance meters and tap changer analyzers are perfect for testing:transformer windings (power transformers, distribution, autotransformers),all types of tap changers,generators,electrical motors,high-current busbar joints,cable splices,and welding joints.In addition, transformer demagnetization can also be done with all RMO-TD instruments.The RMO-TD series contains 3 models, with maximal test currents from 25 A (RMO25TD) to 60 A (RMO60TD).The three independent voltage sense channels enable testing of three windings in series. This enables measurements of winding resistance in every tap position of an on-load tap changer without discharging between the tests.All RMO-TD transformer resistance meters have a built-in tap changer control unit. It enables remote control of on-load tap changer (OLTC) directly from the device. In order to make the most out of this feature, DV-Win software is included which can be programmed to do everything automatically – running winding resistance tests and changing OLTC tap positions.The DV-Win software also enables control and observation of the test process, as well as saving and analyzing the results on a PC. It provides a test report, arranged in a selectable form as an Excel spreadsheet, PDF, Word, or ASCII format. Additionally, DV-Win measures and calculates the OLTC transition time, the ripple and the winding resistance for each tap changing operation. The software can also perform the calculations necessary for the “Heat Run” test.All results can be exported in the report format.

  • Single-Phase Transformer Winding Resistance Meters

    RMO-TT Series - IBEKO Power AB

    RMO-TT series is perfect for measuring winding resistance of inductive objects such as power and distribution transformers or autotransformers. Additionally, every transformer resistance meter from RMO-TT series can analyze:tap changers,generators,electrical motors,high-current busbar joints,cable splices,and welding joints.Transformer demagnetization can also be performed with all RMO-TT instruments.The series is consisted of 3 models, with maximal test current from 40 A (RMO40TT) to 100 A (RMO100TT). RMO100TT is the only portable transformer resistance meter in the market with 100 A DC output current.The three independent channels enable testing of three windings in series. Consequently, a user can measure winding resistance in every tap position of an on-load tap changer without discharging between the tests.In addition to winding resistance measurement, a user can perform a detailed on-load tap changer analysis by analyzing recorded graphs (10 kHz sampling rate) and by measuring vibrations on an external tap changer tank.All RMO-TT instruments have a built-in tap changer control unit. Because of this, it is possible to remotely control on-load tap changer (OLTC) directly from the device. Also, a user can program DV-Win software to do everything automatically – running winding resistance tests and changing OLTC tap positions.The DV-Win software also enables control and observation of the test process, as well as saving and analyzing the results on a PC. It provides a test report, arranged in a selectable form as an Excel spreadsheet, PDF, Word, or ASCII format. Additionally, DV-Win measures and calculates the OLTC transition time, the ripple and the winding resistance for each tap changing operation. The software can also perform the calculations necessary for the “Heat Run” test.All results can be exported in the report format.

Get Help